Description:
Mineral fibrous insulation material on the basis of glass with ECOSE® Technology, supplied
in rolls.
Recommended application – pitched roofs.
Application:
TI 140 U (Unifit 039) with ECOSE®
Technology is intended for application
in pitched roofs as thermal insulation
filling material between the rafters
of a roof frame especially in places
with standard requirements to thermal
insulation properties of the construction.
On the outside of the roof frame the
protective diffusion foil shall be applied
on the mineral fibrous material in order
to prevent prospective condensate from
penetrating into the material and allow
the product to conduct the condensate
away. On the inside a moisture barrier
shall be applied preventing the interior
moisture from penetrating into the
insulation material.
Technical characteristics:
| Technical data |
Symbol |
Value |
Normative prescriptions |
| Declared coefficient of thermal conductivity |
λD |
0,039 W/mK |
EN 12 667, EN 12 939 |
| Reaction to fire |
- |
A1 |
EN 13 501-1 |
| Accuracy class of thickness tolerance |
- |
T2 |
EN 823 |
| Tension strength |
- |
> double weight |
- |
| Air flow resistance |
AFr |
5,1 kPa.s/m2 for d= 100 mm
6,0 kPa.s/m2 for d= 120 mm |
EN 29 053 |
| Diffusion resistance factor |
μ |
1 |
EN 12 086 |
| CE marking |
- |
MW-EN 13162-T2-AFr5 |
EN 13 162 |
| EC certificate of conformity |
ce |
0764–CPD–0122 |
- |
| European standard CEN/CENELEC |
yes |
0001-BK-511-3338-0007-K00A |
- |
| Health safety |
- |
– NIPH No. EX 09 01 82 |
(see safety data sheet) |
Specification
|
Thickness(mm)
|
Width(mm)
|
Length(mm)
|
Thermal conductivity coefficient (λD [W/mK]) |
Thermal resistance (R [m2K/W])
|
| 80 |
1200 |
7700 |
0,039 |
2.05 |
| 100 |
1200 |
7000 |
0,039 |
2.55 |
| 120 |
1200 |
6000 |
0,039 |
3.05 |
| 140 |
1200 |
5000 |
0,039 |
3.55 |
| 160 |
1200 |
4500 |
0,039 |
4.10 |
| 180 |
1200 |
4000 |
0,039 |
4.60 |
| 200 |
1200 |
3500 |
0,039 |
5.10 |
| 220 |
1200 |
3300 |
0,039 |
5.60 |
| 240 |
1200 |
3000 |
0,039 |
6.15 |
|